Vue de la page 18
Operators Guide Inspector 4000
002-5564 RJS, Minneapolis, MN
12
Scan Calib Setup
Storage Inactive
In addition to CALIB, explained in the previous section, there are 3 additional
selectable functions: Scan, Setup and Storage:
Press Select to choose an option.
Press Enter to initiate processing for that option.
Select Scan (from the Main Menu) to display the initial Pass/Fail Analysis screen for the
previously scanned bar code.
Note: A bar code can be scanned at any time except when the unit is printing.
Note: When calibrating the unit or when scanning any bar-code, the background must be the same
color as the bar-code back- groundin the case of the included test symbol sheet the
background should be white.
For example, if your scan is picking up part of a dark table top, slip a white piece of paper
under the bar-code to assure a good read.