Rjs Inspector D4000 Auto Optic (FIRMWARE version A.06 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Scanners Rjs Inspector D4000 Auto Optic (FIRMWARE version A.06 . RJS Inspector D4000 Auto Optic (FIRMWARE version A.06 and Later) User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 84
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Inspector D4000
Auto Optic
Operator’s Guide
Manual P/N 002-7856
Revision: B
July 2013
THIS MANUAL APPLIES ONLY TO FIRMWARE A.06 OR LATER
Use Inspector 4000 Manual (Revision H) for earlier firmware versions
RJS Technologies
701 Decatur Ave North, Suite 107
Minneapolis, MN 55427 U.S.A.
+1 (763) 746-8034
www.rjs1.com
Vue de la page 0
1 2 3 4 5 6 ... 83 84

Résumé du contenu

Page 1 - TO FIRMWARE A.06 OR LATER

Inspector D4000™ Auto Optic Operator’s Guide Manual P/N 002-7856 Revision: B July 2013 THIS MANUAL APPLIES ONLY TO FIRMWARE A.06 OR LA

Page 2

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 1.4 CE: This equipment generates, uses, and can radiate radio frequen

Page 3 - All Rights Reserved

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 3 1.8 Installing Batteries Slide opens the plastic cover on the back of

Page 4

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 1.9 Technical Support Please read the manual and try to understand it,

Page 5 - TABLE OF CONTENTS

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 5 2.0 Warranty 2.1 General Warranty Warranty information: +1 (763) 746-

Page 6 - ARAMETER/ERROR MESSAGE) 34

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 2.3 Service during the Warranty Period If your RJS Inspector D4000 sho

Page 7

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 7 3.0 Introduction 3.1 RJS Inspector D4000 Description and Features The

Page 8

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 3.3 Temperature Specs Do not operate or store your unit or components

Page 9 - 1.0 Preface

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 9 4.0 The RJS Inspector D4000 Auto Optic Note: Calibration plaqu

Page 10

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 5.0 Main Menu Selections 5.1 Calibration Power On When the unit is pow

Page 11

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 11 Verifying that Unit is Calibrated Selecting CALIB sets up the mode t

Page 12

Inspector D4000™ Auto Optic

Page 13 - 2.0 Warranty

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 hold auto-optic scanner head still until you hear a “chirp” sound. Pl

Page 14

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 13 5.2 Scan After finishing calibration press Select and Enter at the s

Page 15 - 3.0 Introduction

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 5.3 Setup Select Setup (from the Main Menu) to view various system par

Page 16

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 15 The next selection is Passing Grade: Passing Grade B Selec

Page 17

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 Three choices are available in Auto Print Mode: 1. Analysis Only: (Fo

Page 18 - Example:

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 17 The next selection is Decode I 2 of 5: Decode I 2of 5 as Std I 2

Page 19 - Calibrating the Unit

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 The next selection allows you to select a range of UPC/EAN symbol magn

Page 20

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 19 5.4 Storage Storage will display as either Storage Inactive or Stor

Page 21 - D4000A Ver x.xx

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 When Storage is active, press Select to move the cursor to the % sign.

Page 22

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 21 6.0 PCS Analysis PCS scanning (overview) This section is an overview

Page 23

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN Copyrights The copyrights in this manual are owned by R

Page 24 - Code 3of9

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 7.0 Scanning Symbols Scanning Techniques  Lay the symbol to be scann

Page 25 - Std 128

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 23 8.0 Pass/Fail Analysis Screen After the symbol is scanned the Pass/

Page 26 - 116 - 150% Mag

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 Below is a sample of scans remaining in multiple scan mode if the last

Page 27

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 25 On the previous tables, all ISO/ANSI symbologies use the traditional

Page 28 - Store and Print buffer

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 9.0 Data Analysis Screens After doing a scan, the Pass/Fail Analysis

Page 29 - Rmn 03% eRmx 90%

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 27 Press Select to bring up the next screen: Ratio: 1.7 F This

Page 30 - Note:

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 The closer the “A” is to the edge, the more likely the Reject. A symbo

Page 31 - 4.0/06/660

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 29 Table 9-A (LED, Bar code Width Deviations) 5 LED Display Pattern Ave

Page 32 - 01 Scans Remain

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 ISO/ANSI Analysis Screens Press Select again to display the first tech

Page 33 - Analysis Screen)

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 31 Press Select to display the next screen: Defects 07% A Appl. Com

Page 35 - --------RRARR+++

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 Press Select to bring up the next screen: Code 3of9 Acceptable

Page 36 - ------RRARR+++++

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 33 10.0 Connect to other Devices Connection to other Devices Connect to

Page 37

Appendix A Operator’s Guide RJS, Minneapolis, MN 002-5564 Appendix A (Symbology Analysis) Symbology Analysis Parameters Table A-1 shows error mess

Page 38

Operator’s Guide Appendix A 002-5564 RJS, Minneapolis, MN 35 Table A-2 (Parameters Checked for Each Symbology) Symbology Ratio ICG Data Char

Page 39 - *1234ABCDEF456*

Appendix A Operator’s Guide RJS, Minneapolis, MN 002-5564 Note 1:  UPC/EAN tolerances: 80 - 89% = .14X 90 - 115% = .30X 116 - 150% = .34X 151

Page 40 - Expect:0

Operator’s Guide Appendix B 002-5564 RJS, Minneapolis, MN 37 Appendix B (ISO/ANSI Decodability) ISO/ANSI Decodability Calculations There is a sp

Page 41 - Connect to Printer

Appendix C Operator’s Guide RJS, Minneapolis, MN 002-5564 Appendix C (Analysis Parameters) ISO/ANSI Parameter Grading

Page 42 - Appendix A Operator’s Guide

Operator’s Guide Appendix C 002-5564 RJS, Minneapolis, MN 39 RJS Inspector D4000 Analysis Parameters Edge Determination This parameter can be gr

Page 43

Appendix C Operator’s Guide RJS, Minneapolis, MN 002-5564 The parameter grade is determined by: 1. Calculating the edge contrast of every element

Page 44 - Expect: 1

Operator’s Guide Appendix C 002-5564 RJS, Minneapolis, MN 41 Defects This parameter can be graded “A,” “B,” “C,” “D,” or “F.” Defects are irreg

Page 45

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN i TABLE OF CONTENTS 1.0 PREFACE 1 1.1 PROPRIETARY STATEMENT 1 1.2 S

Page 46 - ISO/ANSI Parameter Grading

Appendix C Operator’s Guide RJS, Minneapolis, MN 002-5564 If the Reference Decode parameter is “A,” then the overall symbol grade is determined by

Page 47

Operator’s Guide Appendix C 002-5564 RJS, Minneapolis, MN 43 Traditional Analysis Tolerance Graph -100% Tol. +100% ------RRARR+++++ This graph

Page 48 - Modulation

Appendix D Operator’s Guide RJS, Minneapolis, MN 002-5564 Appendix D (Quiet Zone Analysis) Quiet Zone Analysis The RJS Inspector D4000 trims data

Page 49 - Reference Decode

Operator’s Guide Appendix E 002-5564 RJS, Minneapolis, MN 45 Appendix E (Code 128) Code 128 Code 128 can encode all the characters currently enco

Page 50 - Decodability

Appendix E Operator’s Guide RJS, Minneapolis, MN 002-5564 Display of Code 128 The Inspector display can accommodate up to 16 characters. However,

Page 51

Operator’s Guide Appendix E 002-5564 RJS, Minneapolis, MN 47 As indicated before, each of the 3 subsets have “unique” features:  Subset A all

Page 52 - Addendums)

Appendix E Operator’s Guide RJS, Minneapolis, MN 002-5564 Character Set LCD Screen Table E-1 (Code 128 — Subset A) SP ! “ # $ % & ‘

Page 53 - Appendix E (Code 128)

Operator’s Guide Appendix E 002-5564 RJS, Minneapolis, MN 49 Character Set LCD Screen Table E-2 (Code 128 — Subset B) SP ! “ # $ % &

Page 54 - * C L C 1 3 ? *

Appendix E Operator’s Guide RJS, Minneapolis, MN 002-5564 Character Set LCD Screen Table E-3 (Code 128 — Subset C) 00 01 02 03 04 05 06 0

Page 55

Operator’s Guide Appendix E 002-5564 RJS, Minneapolis, MN 51 90 91 92 92 94 95 96 97 98 99 9 9 9 9 9 9 9 9 9 9 0 1 2 3 4

Page 56

Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 TABLE 8-A (CODE IDENTIFIERS RJS INSPECTOR D4000) 24 TABLE 8-B (CODE I

Page 57

Appendix E Operator’s Guide RJS, Minneapolis, MN 002-5564 GS1-128 Symbology Specification When a Code 128 symbol is decoded AND the first characte

Page 58

Operator’s Guide Appendix F 002-5564 RJS, Minneapolis, MN 53 Appendix F (Magnifications) UPC/EAN Magnifications & Bar Width Deviations UPC and

Page 59

Appendix G Operator’s Guide RJS, Minneapolis, MN 002-5564 Appendix G (Aperture Selection) The D4000 Auto Optic has four different aperture (ligh

Page 60 - Appendix E Operator’s Guide

Operator’s Guide Appendix H 002-5564 RJS, Minneapolis, MN 55 Appendix H (Print Functions) Print Functions Scanned data may be printed if the RJS I

Page 61 - Appendix F (Magnifications)

Appendix H Operator’s Guide RJS, Minneapolis, MN 002-5564 When printing the buffer in multiple scan mode, don’t initiate printing before all scans

Page 62 - Appendix G Operator’s Guide

Operator’s Guide Appendix I 002-5564 RJS, Minneapolis, MN 57 Appendix I (Computer Mode) Output Data When the Computer is enabled during Setup, as

Page 63 - Analysis Only

Appendix I Operator’s Guide RJS, Minneapolis, MN 002-5564 Inspector D4000A Revision A.06 02-Scan Average Analysis C

Page 64 - Appendix H Operator’s Guide

Operator’s Guide Appendix J 002-5564 RJS, Minneapolis, MN 59 Appendix J (Battery Displays) Battery Displays If the “Low Battery” condition display

Page 65 - Appendix I (Computer Mode)

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 Appendix K (Bar code definitions) Achieved Width The calculated element width based

Page 66 - Text Analysis

Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 61 Bar code A group of parallel bars and spaces constituting characters that ar

Page 67 - Replace Battery

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN iii APPENDIX D (QUIET ZONE ANALYSIS) 44 QUIET ZONE ANALYSIS 44 TABLE

Page 68 - Appendix K Operator’s Guide

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 Bit The narrowest code element (bar of space) that may contain information. Character T

Page 69 - Operator’s Guide Appendix K

Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 63 Decode Determining the information which has been encoded in a bar code symbol. Deco

Page 70

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 Edge Contrast (EC) See Edge Contrast(min) The difference between the space reflec

Page 71

Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 65 Element Reflectance Non-uniformity (ERN) The reflectance difference between the highe

Page 72

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 The global threshold is drawn through the middle of a profile, to distinguish spaces abo

Page 73

Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 67 Inter-character Gap In discrete barcodes, the space that separates two adjacen

Page 74

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 The greatest reflectance value in a scan reflectance profile including quiet zone. (

Page 75

Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 69 The narrowest expected bar or space width. Moving Beam Scanner A laser device t

Page 76

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 The ability to read a bar code symbol from any angle as long as the bar code passes acro

Page 77

Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 71 Print Contrast Signal (PCS) A comparison between the reflectance (brightness dif

Page 79

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 This parameter grade can be “A” or “F.” The reflec-tance value of the “lightest” space

Page 80

Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 73 A bar code or symbol that uses a checking algorithm that can be applied to each

Page 81

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 The material (paper, plastic, metal, etc.) upon which a bar code symbol is “printed” or

Page 82 - 0.0 = F

Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 75 Technology Park/Atlanta, P.O. Box 105113 Atlanta, GA 30348-5115 Threshold (Global T

Page 83

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 Void White or light reflective area in a bar caused by a printing error that

Page 84

Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 1 1.0 Preface 1.1 Proprietary Statement The RJS Inspector D4000 Operat